CNI 508N1 ASSEMBLY
Coupling/decoupling assembly for unshielded and shielded high-speed communication lines up to 1GBit/s
- Application
- Standards
- CN 508N1 - Coupling Network
- SPN 508N1 - Surge Protection Network
- CNI 508N1 - Coupling/Decoupling Network
- Testing high-speed communication lines
- Meeting PoE and PoE+ Requirements
- Technical Data
(PDF-File / 1.1 MB)

Highlights
- Coupling to unshielded and shielded lines with up to 4 pairs
- Surge test voltage up to 4kV (1.2/50us)
- Data transfer up to 1,000MBit/s
- Residual voltage max. 20V at 2kV
- Ringwave test voltage up to 4kV (0.5us/100kHz)
- Burst test voltage up to 4kV (5/50ns)
- DUT/AE connection via RJ45 connectors
- Compatible to PoE and PoE+ requirements
Top
Application
Top
CNI 508N1 - Coupling/decoupling assembly for unshielded and shielded high-speed communication lines
The EM TEST CNI 508N1 assembly is the first coupling/decoupling network available on the market to couple Surge onto unshielded and shielded high-speed communication lines with data rates up to 1,000MBit/s.
The CNI 508N1 assembly consists of a coupling network CN 508N1, a decoupling network CNI 508N1 and a protection equipment SPN 508N1 to limit the residual voltage at the AE side.
Additionally, the CNI 508N1 can be used as a coupling/decoupling network to apply Surge as well as Ringwave and Burst pulses to shielded lines.
The CNI 508N1 assembly consists of a coupling network CN 508N1, a decoupling network CNI 508N1 and a protection equipment SPN 508N1 to limit the residual voltage at the AE side.
Additionally, the CNI 508N1 can be used as a coupling/decoupling network to apply Surge as well as Ringwave and Burst pulses to shielded lines.
Top
Standards
Top
- EN 61000-4-12
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-6-1
- EN 61000-6-2
- IEC 61000-4-12
- IEC 61000-4-4
- IEC 61000-4-5
Top
SPN 508N1 - Surge Protection Network
Top
Surge Protection Network for unshielded and shielded high-speed communication lines
Top
CNI 508N1 - Coupling/Decoupling Network
Top
CDN for undshielded and shielded high-speed communication lines
The CNI 508N1 is a specifically designed CDN for testing high-speed communication lines. Its unique design allows data rates of up to 1,000MBit/s to be transmitted without degradation by the coupling/decoupling network. The decoupling network protects the auxiliary equipment limiting the residual voltage to max. 20V@2kV for common-mode surge test pulses.
Moreover, the CNI 508N1 fully supports PoE and PoE+ standard requirements as per IEEE 802.3.
The CNI 508N1 may also be used for testing shielded cables as per IEC/EN 61000-4-5, Fig. 16. It simplifies the test set-up and offers proper decoupling of the auxiliary equipment as well as a high safety for the operator as the surge is coupled through the CNI 508N1 rather than being directly applied to the metallic case of the DUT.
Additionally, the CNI 508N1 may also be used to couple Ringwave pulse (0.5us/100kHz) and burst pulses to shielded cables.
Moreover, the CNI 508N1 fully supports PoE and PoE+ standard requirements as per IEEE 802.3.
The CNI 508N1 may also be used for testing shielded cables as per IEC/EN 61000-4-5, Fig. 16. It simplifies the test set-up and offers proper decoupling of the auxiliary equipment as well as a high safety for the operator as the surge is coupled through the CNI 508N1 rather than being directly applied to the metallic case of the DUT.
Additionally, the CNI 508N1 may also be used to couple Ringwave pulse (0.5us/100kHz) and burst pulses to shielded cables.
Top
Testing high-speed communication lines
Top
Test Set-up recommendation for unshielded high-speed communication lines
Top
Meeting PoE and PoE+ Requirements
Top
Test Set-up recommendations for PoE and PoE+
Using the SPN 508N1 Surge Protection Network to decouple the surge pulses from the auxiliary equipment directly influences the capabilities of the CN 508N1 and the CNI 508N1 to comply with the PoE and the PoE+ requirements. It is therefore recommended to install the PoE supply between the SPN 508N1 and the CNI 508N1 for proper operation of the PoE system.
Top